NOTICE: This version of the NSF Unidata web site (archive.unidata.ucar.edu) is no longer being updated.
Current content can be found at unidata.ucar.edu.
To learn about what's going on, see About the Archive Site.
Don Murray wrote:
I'm not sure the IDV handles the 2D dimensions. I would suggest sending a note to support-idv@xxxxxxxxxxxxxxxx.Don
If the file is RAF/Nimbus, the second dimension is not required for one sample per second data.
On 4/10/11 12:39 PM, Sebastian Engelstaedter wrote:Hi all, I am new to IDV but it looks like a powerful tool. I want to plot aircraft track data which come in netCDF format. However, IDV is unable to read in the current netcdf file I have. Can someone point me to the correct format. At the moment the netcdf file looks something like this: dimensions: data_point = UNLIMITED ; // (28980 currently) sps01 = 1 ; variables: int Time(data_point) ; Time:long_name = "time of measurement" ; Time:units = "seconds since 2011-04-04 00:00:00 +0000" ; Time:_FillValue = -1 ; Time:standard_name = "time" ; float IAS_RVSM(data_point, sps01) ; IAS_RVSM:long_name = "Indicated air speed from the aircraft RVSM (air data) system. " ; IAS_RVSM:units = "m s-1 " ; IAS_RVSM:_FillValue = -9999.f ; IAS_RVSM:Frequency = 1s ; IAS_RVSM:Number = 516s ; byte IAS_RVSM_FLAG(data_point, sps01) ; IAS_RVSM_FLAG:long_name = "Flag for Indicated air speed from the aircraft RVSM (air data) system. " ; IAS_RVSM_FLAG:units = 1s ; IAS_RVSM_FLAG:_FillValue = -1b ; IAS_RVSM_FLAG:Frequency = 1s ; float TAS_RVSM(data_point, sps01) ; TAS_RVSM:long_name = "True air speed from the aircraft RVSM (air data) system and deiced temperature. " ; TAS_RVSM:units = "m s-1 " ; TAS_RVSM:_FillValue = -9999.f ; TAS_RVSM:Frequency = 1s ; TAS_RVSM:Number = 517s ; TAS_RVSM:standard_name = "platform_speed_wrt_air" ; byte TAS_RVSM_FLAG(data_point, sps01) ; TAS_RVSM_FLAG:long_name = "Flag for True air speed from the aircraft RVSM (air data) system and deiced temperature. " ; TAS_RVSM_FLAG:units = 1s ; TAS_RVSM_FLAG:_FillValue = -1b ; TAS_RVSM_FLAG:Frequency = 1s ; float TAT_DI_R(data_point, sps01) ; TAT_DI_R:long_name = "True air temperature from the Rosemount deiced temperature sensor. " ; TAT_DI_R:units = "degK " ; TAT_DI_R:_FillValue = -9999.f ; TAT_DI_R:Frequency = 1s ; TAT_DI_R:Number = 520s ; TAT_DI_R:standard_name = "air_temperature" ; .... Any help is much appreciated. Best wishes, Sebastian
-- Larry Oolman Department of Atmospheric Science University of Wyoming Dept. 3038, 1000 E. University Ave. Laramie, WY 82071 ldoolman@xxxxxxxx http://www-das.uwyo.edu
idvusers
archives: