19990119: GARP upperair level widget



>From: Robert Mullenax <address@hidden>
>Organization: .
>Keywords: 199901191439.HAA10295

>I have looked through all info I can find on GARP, and cannot find
>the answer to this.  Is it possible to change the levels that are
>available on the upper-air selection?  I would like to have the option
>of looking at 30, 20 and 10mb, instead of going from 50mb to top.
>I know this is a breeze with the command line, but I would like to
>be able to do it with GARP.  
>
>Thanks,
>Robert Mullenax
>

Robert,

The Widget defaults are defined in the $GARPHOME/config/Garp_defaults
file. In this file you will find a line:
upalevels       : Surface,1000,925,850,700,500,400,300,250,200,150,100,70,50,Top

All you need to do is edit the level list and restart Garp.

Steve Chiswell
Unidata User Suport