20050321: RUC data



Ben,

That is correct. The RUC runs are "extended" to 12 hours at three hour
intervals. The other times, the model is available to 3 hours.

Steve Chiswell
Unidata User SUpport



On Mon, 2005-03-21 at 14:44, address@hidden wrote:
> Howdy all,
> 
> Did I miss something here?  Looking through my data, I've only got RUC output 
> to
> 12hrs for the 0,3,6,9,12,15,18, and 21Z RUC runs.  The rest of the time I only
> have out to 3hrs.  Here's my pqact.conf entry:
> 
> HDS     ...... KWB. ([0-3][0-9])([0-2][0-9]).*/mRUC
>         FILE    data/hds/(\1:yy)(\1:mm)\1\2_ruc.grb
> 
> Any ideas?
> 
> 
> Thanks,
> Ben