Hi Jacob- > Full Name: Jacob Gore > Email Address: address@hidden > Organization: Educational > Package Version: 2.7a1 build date:2009-02-25 20:05 UTC > Operating System: Linux > Hardware: Java: home: /home/idv/IDV_2.7a1/jre version: 1.6.0_11 j3d:1.5.2 fcs > (build4) > Description of problem: When I save a bundle with a temperature-based water > vapor satellite display overlaidwith RUC wind data, the IDV will not display > the water vapor image when I open the bundle. The IDV downloads the > satellite data and sets the time steps correctly, but the satellite image > itself does not show up on the map. The wind data from the RUC model shows > up fine, however. I tried saving a bundle from two different satellite > servers, but nothing works. I have exported the bundle and have attached it > to this message for you. The data is there. The range on the color table is -10 to -60, but the data are in K with a range of 0 to 263. If you change the display units to Celsius and then set the range to -10 to -60, you should see what you want. I'm trying to figure out how this could happen. When you created the display, did you change the display units from K to Celsius before setting the range on the color table? Thanks for any additional info you can provide. Don Ticket Details =================== Ticket ID: JCY-183241 Department: Support IDV Priority: Normal Status: Open