NOTICE: This version of the NSF Unidata web site (archive.unidata.ucar.edu) is no longer being updated.
Current content can be found at unidata.ucar.edu.

To learn about what's going on, see About the Archive Site.


[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[IDV #JCY-183241]: Bundle Error With Satellite Data



Hi Jacob-

> Full Name: Jacob Gore
> Email Address: address@hidden
> Organization: Educational
> Package Version: 2.7a1 build date:2009-02-25 20:05 UTC
> Operating System: Linux
> Hardware: Java: home: /home/idv/IDV_2.7a1/jre version: 1.6.0_11 j3d:1.5.2 fcs 
> (build4)
> Description of problem: When I save a bundle with a temperature-based water 
> vapor satellite display overlaidwith RUC wind data, the IDV will not display 
> the water vapor image when I open the   bundle.  The IDV downloads the 
> satellite data and sets the time steps correctly, but   the satellite image 
> itself does not show up on the map.  The wind data from the RUC model shows 
> up fine, however.  I tried saving a bundle from two different satellite     
> servers,  but nothing works.  I have exported the bundle and have attached it 
> to this message for you.

The data is there. The range on the color table is -10 to -60, but the data are 
in
K with a range of 0 to 263.  If you change the display units to Celsius and then
set the range to -10 to -60, you should see what you want.

I'm trying to figure out how this could happen.  When you created the display, 
did 
you change the display units from K to Celsius before setting the range on the 
color table? 

Thanks for any additional info you can provide.

Don 


Ticket Details
===================
Ticket ID: JCY-183241
Department: Support IDV
Priority: Normal
Status: Open