NOTICE: This version of the NSF Unidata web site (archive.unidata.ucar.edu) is no longer being updated.
Current content can be found at unidata.ucar.edu.
To learn about what's going on, see About the Archive Site.
Hi Paul. According to http://www.crh.noaa.gov/lmk/?n=vil_density VIL Density = VIL/Echo Top Therefore you need to set up a formula within the IDV to calculate this derived field from the radar data. Please see http://www.unidata.ucar.edu/software/idv/docs/workshop/formulas/index.html Let us know if you have questions. -Julien > Full Name: Paul Bouchereau > Email Address: address@hidden > Organization: None > Package Version: 2.9 build date:2010-05-27 15:48 UTC > Operating System: Windows Vista > Hardware: Java: home: E:\Program Files\IDV_2.9\jre version: 1.6.0_20 > j3d:1.5.2 fcs (build4) > Description of problem: > > I have been looking thru the User Guide and I can't find a way to > calculate VIL Density. Is there a way I can do this? > > Ticket Details =================== Ticket ID: ATO-121022 Department: Support IDV Priority: Normal Status: Closed