[LDM #HMA-788722]: LDM problem



John,

Your clock might be correct, but according to our LDM log file,
your LDM is still asking for data that's in the future:

Dec 21 08:24:34 uni7 adiabat.rwic.und.edu(feed)[31341] NOTE: Starting 
Up(6.6.5/6): 20071221142433.210 TS_ENDT {{NEXRAD2,  ".*"}}, 
SIG=594e9395cfbf4a3d842e2939be77ec3c, Primary 

The above message was logged by an upstream LDM in response to
a connection from Adiabat.  The connection occurred at
2007-12-21 08:24:34 UTC and a request was made for data beginning
at 2007-12-21 14:24:33.210 UTC.  The fact that the request is
almost exactly 6 hours in the future and your timezone is -6
hours makes me suspect something funny with the timezone
information on your system.  What's the output of the commands
"date -u" and "date"?

Regards,
Steve Emmerson